Looking for a BSL-2 Laboratory Space?
January 31, 2023
Five things to consider when scoping out a BSL-2 lab space to keep your workers safe.
More and more commercial building landlords set aside laboratory space to lease. When scoping out possible options for existing laboratory space, beyond the research experiment, you need to consider worker safety. Being risk averse is a good practice when walking through potential laboratory spaces for your next research project. Here are 5 things to consider when scoping out a BSL-2 laboratory.
1. Establish Your Criteria Through Safety Guidelines
Safety in a laboratory is paramount! There are guidelines available to you that can serve as your criteria or provide a checklist to ensure that when evaluating a space, it “checks the boxes.” When looking for a new home, most people have their “dealbreakers” (e.g., must have 3 bedrooms and a walk-in pantry) versus their “bonuses” (e.g., pool and wood-burning fireplace). The same idea can be applied when looking at a potential BSL-2 laboratory space. What are your dealbreakers?
Establishing your safety guidelines before you even call a landlord to inquire about a space is a good way to communicate what kind of laboratory space is needed. The Biosafety in Microbiological and Biomedical Laboratories (BMBL) published by the Centers for Disease Control and Prevention (CDC) and the National Institutes of Health (NIH) provides guidance on the laboratory space requirements. The World Health Organization (WHO)’s Laboratory Biosafety Manual is another source that will guide you how to approach your laboratory with a balanced risk assessment.
Please be informed, the BMBL is a guideline and not a regulation. If a laboratory space does not meet all of the statements within the guidelines, you can conduct a risk assessment to evaluate the potential risk and impact to your research, workers and the surrounding environment. A workaround solution such as an administrative control can provide an easy resolution. Workaround administrative control solutions will require training and monitoring so factor that into your decision-making.
Preplanning will expedite decision-making and protect your most valuable personnel as well as the tenants who share the building. If you are an employer or landlord and in need of a space evaluation, risk assessment or a second opinion if whether a space or building qualifies for a biological containment laboratory, contact us for more information.
2. Adequate Inward Directional Airflow
Inward directional airflow that does not recirculate outside of the BSL-2 laboratory is highly recommended by the BMBL to ensure that sufficient air is being drawn into the BSL-2 laboratory and to prevent aerosol transmission from the laboratory into another part of the building. Inward directional airflow draws air into the laboratory from the “clean” areas (e.g., corridor outside of a laboratory) and toward “potentially contaminated” areas (e.g., a biological safety cabinet [BSC]). Although not a requirement, the BMBL and WHO Laboratory Biosafety Manual recommends that a BSL-2 laboratory has inward directional airflow. The rationale is to eliminate the risk of others in the building from being exposed to the biological and/or chemical materials that could be released into the space inadvertently.
Verification of directional airflow can be accomplished and documented by a Testing and Air Balance (TAB) Report or by an engineer’s testing and certification. A pressure differential target value is at least .05 In. H2O (15 Pascals) which approximates 100 CFM passing through the crack area of the entry door. Ask the landlord for a TAB Report so you can verify if there is directional airflow. Not sure where to start or how to read a TAB Report? Contact us and we can help you.
3. Biological Safety Cabinet (BSC) Placement
The BSC is a key area where your manipulations will occur in the BSL-2 laboratory. When walking through the laboratory, consider where the BSC will be placed. You want to make sure that people walking by do not disrupt the air inflow into the BSC. Rule of thumb is to place the BSC away from doors and common pathways within the laboratory. If you have limited options, put a demarcation line on the floor (red tape works well) as a visual aid as to where not to walk. Train and periodically observe your laboratory personnel to ensure they do not cross the demarcation line when walking past the BSC.
Ideally, the BSC should be placed as far as possible from the entryway. The objective of directional airflow is to draw air from the “clean” areas toward the potentially contaminated areas. The BSC is the most potentially contaminated space within the laboratory. Having your BSC placed far from the entryway reduces the risk of exposure and minimizes BSC airflow disruption.
One last point about BSCs and their required annual testing. There needs to be at least 12 inches between the HEPA filter of a Class II type A2 BSC for scanning the HEPA filter. Make sure to check floor-to-ceiling clearance for the height of the BSC you will be using. Although BSC stands are adjustable, you do not want to have the BSC so low that it impacts the worker’s ergonomics. BSC heights are generally about 8 feet so you will need at least a floor-to-ceiling height of 9 feet.
4. Look Down At The Floor
Slips, trips, falls and spills are always a great risk in the workplace. The BSL-2 laboratory floor should be smooth, slip-resistant flooring. Sealed flooring is recommended. Watch out for manufactured floors with grooves or grouted floors that cannot be easily cleaned. We suggest verifying that the flooring material is chemical resistant and antimicrobial. Carpets and rugs are unacceptable.
5. Let This Sink In
You would be surprised how many times our experts evaluated laboratories that do not have sinks at the entry/exit ways. Good laboratory practice is to wash your hands before leaving the laboratory to minimize potential contamination of door hardware. Ideally, the sink should be located close to the laboratory exit so that after doffing PPE, the worker can wash their hands.
6. It Doesn’t Hurt To Ask
Surprise! We have a 6th tip. Discuss with the landlord and document what needs to be installed, repaired, or replaced before you take occupancy. Any annual maintenance items should also be discussed (e.g., filter changes, lighting relamping, etc.) and discuss deliveries to the facility (e.g., laboratory samples, bottled gasses, etc.). This effort will pay off in the future with you being a long-term tenant and establishing an amicable tenant and landlord relationship.
Next Steps
Are you interested in scoping out a biological containment (BSL-2 or BSL-3) laboratory? Consider inviting one of World BioHazTec’s experts along. We can evaluate the space and perform a risk assessment to determine if the containment laboratory space can accommodate your laboratory needs. Our services can include any or all needs for reviewing the TAB Report, assisting with equipment placement and evaluating the overall layout of the laboratory. Our report will provide you and the landlord a basis for discussion on lease modifications and tenant upgrades to move forward with leasing the space.